Request a Quote
Leave Your Message
Products Categories
Featured Products

China Suppliers Factory Screw Water Ring Vacuum Pump Unit for Enhanced Vacuum Performance

Introducing the advanced Screw Water Ring Vacuum Pump Unit, a highly efficient vacuum solution designed for optimal performance. This unit features a top-tier Screw pump as the main pump, complemented by 2BV or 2BE water ring pumps as pre-stage pumps. The primary function of the water ring pump is to generate the essential pre-vacuum required for the Screw pump to operate effectively. As a leading China supplier and factory of vacuum pump systems, we ensure that our products are engineered for reliability and performance. With each additional stage of Screw pumps connected, the ultimate vacuum capability of our unit increases significantly, allowing for exceptional vacuum levels that meet diverse industrial needs. Trust in our expertise and choose our Screw Water Ring Vacuum Pump Unit for superior vacuum technology

    Product Characteristics

    01

    This is a paragraph

    This is a paragraph

    02

    This is a paragraph

    This is a paragraph

    03

    This is a paragraph

    This is a paragraph

    04

    This is a paragraph

    This is a paragraph

    05

    This is a paragraph

    This is a paragraph

    06

    This is a paragraph

    This is a paragraph

    07

    This is a paragraph

    This is a paragraph

    08

    This is a paragraph

    This is a paragraph

    09

    This is a paragraph

    This is a paragraph

    10

    This is a paragraph

    This is a paragraph

    11

    This is a paragraph

    This is a paragraph

    12

    This is a paragraph

    This is a paragraph

    13

    This is a paragraph

    This is a paragraph

    14

    This is a paragraph

    This is a paragraph

    Product Parameters

    Unit Model Pump Model Draw Rate
    L/S
    Absolute Vacuum
    Pa
    Total Power
    KW
    Main Pump Pre-stage Pump
    JZJ2B30-1 ZJP30 2BV5110 30 267 5.5
    JZJ2B70-1 ZJP70 2BV5111 70 7
    JZJ2B150-1 ZJP150 2BV5131 150 14
    JZJ2B300-2 ZJP300 2BV5161 300 19
    JZJ2B300-1 ZJP300 2BE1 202 300 26
    JZJ2B600-2 ZJP600 2BE1 203 600 44.5
    JZJ2B600-1 ZJP600 2BE1 252 600 52.5
    JZJ2B70-2.1 ZJP70 ZJP30/2BV5110 70 25 7
    JZJ2B150-2.1 ZJP150 ZJP70/2BV5111 150 10
    JZJ2B300-2.1 ZJP300 ZJP150/2BV5131 300 18
    JZJ2B600-2.2 ZJP600 ZPJ300/2BV5161 600 26.5
    JZJ2B1200-2.2 ZJ1200 ZJP600/2BE1203 1200 55.5
    JZJ2B1200-2.1 ZJ1200 ZJP600/2BE1252 1200 63.5
    JZJ2B2500-2.1 ZJ2500 ZJ1200/2BE1303 2500 133
    JZJ2B5000-4.1 ZJ5000 ZJ1200/2BE1303 5000 176
    JZJ2B70-2.1.1 ZJP70 ZJP30/ZJP30/2BV5110 70 0.5 8.5
    JZJ2B150-2.2.1 ZJP150 ZJP70/ZJP30/2BV5110 150 10
    JZJ2B300-2.2.1 ZJP300 ZJP150/ZJP70/2BV5111 300 14
    JZJ2B600-2.2.1 ZJP600 ZJP300/ZJP150/2BV5131 600 23.5
    JZJ2B1200-2.2.2 ZJ1200 ZJP600/ZJP300/2BV5161 1200 37.5
    JZJ2B1200-2.2.1 ZJ1200 ZJP600/ZJP300/2BE1202 1200 51.5
    JZJ2B2500-2.2.1 ZJ2500 ZJ1200/ZJP600/2BE1252 2500 85.5
    JZJ2B2500-4.2.1 ZJ2500 ZJP600/ZJP300/2BE1202 2500 55.5
    JZJ2B5000-4.2.1 ZJ5000 ZJ1200/ZJP600/2BE1252 5000 118.5
    Important Notes
    • 1 The series in the table represents the recommended standards. Due to the varying working conditions in actual production applications, the gas intake and pressure will undergo many changes. Therefore, during the selection process, calculations or reference to the usage of existing equipment should be conducted based on the actual vacuum extraction process, gas release process, condensation of non-volatile gases, time variations of the intake pressure, etc.
    • 2 The technical indicators of the single pump are detailed in the respective pump parameter tables.
    • 3 The maximum intake pressure refers to the highest pressure that the main pump can start at. If it operates for a long time at a pressure higher than this, it will cause the main pump to overload.
    • 4 If the vacuum pump motor, electrical contact vacuum gauge/pressure transmitter, and electrical control cabinet need to be explosion-proof, please specify during the order. The 2BV5 water ring vacuum pump in the table should be correspondingly changed to the 2BV6 series.
    Frequently Asked Questions
    Q What does the unit model designation (e.g., JZJ2B300-2) indicate?
    A The unit model designation encodes key configuration information. "JZJ2B" identifies the product series (Roots + water ring vacuum unit), the number following indicates the draw rate (e.g., 300 L/S), and the suffix (e.g., -2 or -2.1) describes the number of pump stages and configuration type in the pre-stage pump assembly.
    Q How should I select the correct unit model for my application?
    A Selection should be based on your actual vacuum extraction process requirements, including the required draw rate (L/S), target absolute vacuum level (Pa), gas release characteristics, condensation of non-volatile gases, and time variations of intake pressure. It is recommended to perform engineering calculations or reference existing equipment usage under similar conditions rather than relying solely on the standard table values.
    Q What is the difference between units achieving 267 Pa, 25 Pa, and 0.5 Pa absolute vacuum?
    A The difference lies in the number of pump stages in the pre-stage pump configuration. Units achieving 267 Pa use a single-stage water ring pump as the pre-stage pump. Units achieving 25 Pa use a two-stage configuration (one Roots pump + one water ring pump). Units achieving 0.5 Pa use a three-stage configuration (two Roots pumps + one water ring pump), providing progressively deeper vacuum levels at the cost of additional power consumption.
    Q What happens if the main pump operates above its maximum intake pressure for extended periods?
    A Operating the main pump continuously at pressures above the specified maximum intake pressure will cause the main pump motor to overload. This can lead to excessive heat generation, accelerated wear of internal components, motor burnout, and ultimately premature failure of the pump unit. It is critical to ensure the system pressure remains within the rated operating range during sustained operation.
    Q When is an explosion-proof specification required, and what changes does it involve?
    A An explosion-proof specification is required when the operating environment contains flammable gases, vapors, or dust that could pose an ignition risk. In such cases, the vacuum pump motor, electrical contact vacuum gauge or pressure transmitter, and the electrical control cabinet must all meet explosion-proof standards. Specifically, the 2BV5 series water ring vacuum pump must be replaced with the equivalent 2BV6 series. This requirement must be clearly stated at the time of ordering.
    Q Where can I find detailed technical specifications for individual pumps used in these units?
    A Detailed technical indicators for each individual pump — including the ZJP series Roots pumps, ZJ series Roots pumps, 2BV5/2BV6 water ring vacuum pumps, and 2BE1 series water ring vacuum pumps — are provided in their respective pump parameter tables. Please refer to the individual pump datasheets or contact our technical team for comprehensive performance curves and specifications.

    Leave Your Message