China Suppliers Factory Screw Water Ring Vacuum Pump Unit for Enhanced Pre-Vacuum Performance

,

The Screw water ring vacuum pump unit is an advanced vacuum solution that combines a high-efficiency screw pump with 2BV or 2BE water ring pumps as pre-stage pumps. This innovative design allows the water ring pump to create the essential pre-vacuum required for optimal screw pump operation. Acting as a booster pump, the screw pump significantly enhances the vacuum performance of the unit. By adding more stages of screw pumps, users can increase the ultimate vacuum level by one order of magnitude. As a leading manufacturer in China, we pride ourselves on delivering top-quality vacuum systems, making us a trusted supplier in the industry. Our factory employs cutting-edge technology to ensure that every unit meets the highest standards of performance and reliability.

,

    Product Characteristics

    01

    This is a paragraph

    This is a paragraph

    02

    This is a paragraph

    This is a paragraph

    03

    This is a paragraph

    This is a paragraph

    04

    This is a paragraph

    This is a paragraph

    05

    This is a paragraph

    This is a paragraph

    06

    This is a paragraph

    This is a paragraph

    07

    This is a paragraph

    This is a paragraph

    08

    This is a paragraph

    This is a paragraph

    09

    This is a paragraph

    This is a paragraph

    10

    This is a paragraph

    This is a paragraph

    11

    This is a paragraph

    This is a paragraph

    12

    This is a paragraph

    This is a paragraph

    13

    This is a paragraph

    This is a paragraph

    14

    This is a paragraph

    This is a paragraph

    Product Parameters

    Unit Model Pump Model Draw Rate
    (L/S)
    Absolute Vacuum
    (Pa)
    Total Power
    (KW)
    Main Pump Pre-stage Pump
    JZJ2B30-1 ZJP30 2BV5110 30 267 5.5
    JZJ2B70-1 ZJP70 2BV5111 70 7
    JZJ2B150-1 ZJP150 2BV5131 150 14
    JZJ2B300-2 ZJP300 2BV5161 300 19
    JZJ2B300-1 ZJP300 2BE1 202 300 26
    JZJ2B600-2 ZJP600 2BE1 203 600 44.5
    JZJ2B600-1 ZJP600 2BE1 252 600 52.5
    JZJ2B70-2.1 ZJP70 ZJP30/2BV5110 70 25 7
    JZJ2B150-2.1 ZJP150 ZJP70/2BV5111 150 10
    JZJ2B300-2.1 ZJP300 ZJP150/2BV5131 300 18
    JZJ2B600-2.2 ZJP600 ZPJ300/2BV5161 600 26.5
    JZJ2B1200-2.2 ZJ1200 ZJP600/2BE1203 1200 55.5
    JZJ2B1200-2.1 ZJ1200 ZJP600/2BE1252 1200 63.5
    JZJ2B2500-2.1 ZJ2500 ZJ1200/2BE1303 2500 133
    JZJ2B5000-4.1 ZJ5000 ZJ1200/2BE1303 5000 176
    JZJ2B70-2.1.1 ZJP70 ZJP30/ZJP30/2BV5110 70 0.5 8.5
    JZJ2B150-2.2.1 ZJP150 ZJP70/ZJP30/2BV5110 150 10
    JZJ2B300-2.2.1 ZJP300 ZJP150/ZJP70/2BV5111 300 14
    JZJ2B600-2.2.1 ZJP600 ZJP300/ZJP150/2BV5131 600 23.5
    JZJ2B1200-2.2.2 ZJ1200 ZJP600/ZJP300/2BV5161 1200 37.5
    JZJ2B1200-2.2.1 ZJ1200 ZJP600/ZJP300/2BE1202 1200 51.5
    JZJ2B2500-2.2.1 ZJ2500 ZJ1200/ZJP600/2BE1252 2500 85.5
    JZJ2B2500-4.2.1 ZJ2500 ZJP600/ZJP300/2BE1202 2500 55.5
    JZJ2B5000-4.2.1 ZJ5000 ZJ1200/ZJP600/2BE1252 5000 118.5
    📋 Important Notes
    • 1 The series in the table represents the recommended standards. Due to the varying working conditions in actual production applications, the gas intake and pressure will undergo many changes. Therefore, during the selection process, calculations or reference to the usage of existing equipment should be conducted based on the actual vacuum extraction process, gas release process, condensation of non-volatile gases, time variations of the intake pressure, etc.
    • 2 The technical indicators of the single pump are detailed in the respective pump parameter tables.
    • 3 The maximum intake pressure refers to the highest pressure that the main pump can start at. If it operates for a long time at a pressure higher than this, it will cause the main pump to overload.
    • 4 If the vacuum pump motor, electrical contact vacuum gauge/pressure transmitter, and electrical control cabinet need to be explosion-proof, please specify during the order. The 2BV5 water ring vacuum pump in the table should be correspondingly changed to the 2BV6 series.
    Frequently Asked Questions
    Q What does the unit model naming convention (e.g., JZJ2B300-2) represent?
    A The unit model designation encodes the pump series (JZJ2B), the draw rate capacity (e.g., 300 L/S), and the configuration stage number (e.g., -2 for a two-stage pre-pump arrangement). The suffix also indicates the specific pre-stage pump combination used in the unit.
    Q What is the significance of the absolute vacuum values (267 Pa, 25 Pa, and 0.5 Pa) listed in the table?
    A These values represent the ultimate absolute vacuum achievable by each unit configuration. Single-stage pre-pump units reach approximately 267 Pa, two-stage configurations achieve around 25 Pa, and three-stage configurations can reach as low as 0.5 Pa — suitable for high-vacuum process applications.
    Q When should I choose a multi-stage pre-pump configuration over a single-stage unit?
    A Multi-stage pre-pump configurations are recommended when your process requires a deeper vacuum level. For example, if your application demands absolute pressures below 25 Pa, a three-stage configuration (reaching 0.5 Pa) would be more appropriate than a single-stage unit limited to 267 Pa.
    Q What happens if the main pump operates above its maximum intake pressure for extended periods?
    A Operating the main pump above its maximum intake pressure for prolonged periods will cause the pump motor to overload. This can result in overheating, increased wear, reduced service life, and potential equipment failure. It is critical to ensure the system operates within the specified pressure range during normal production.
    Q How do I select the right unit for my specific vacuum process requirements?
    A Selection should be based on a thorough analysis of your actual process conditions, including the required draw rate (L/S), target vacuum level (Pa), gas release characteristics, condensation of non-volatile gases, and how intake pressure varies over time. It is recommended to perform engineering calculations or reference existing similar equipment installations before finalizing the unit model.
    Q Can these vacuum pump units be configured for use in explosive or hazardous environments?
    A Yes. If explosion-proof requirements apply to the motor, electrical contact vacuum gauge, pressure transmitter, or electrical control cabinet, this must be specified at the time of ordering. In such cases, the 2BV5 series water ring vacuum pumps listed in the table must be replaced with the equivalent 2BV6 explosion-proof series.