Request a Quote
Leave Your Message
Products Categories
Featured Products

China Suppliers Factory Screw Water Ring Vacuum Pump Unit - Boosting Pre-Vacuum Performance

The Screw Water Ring Vacuum Pump Unit is an advanced vacuum solution that combines a high-performance Screw pump as the main component with 2BV or 2BE water ring pumps serving as efficient pre-stage pumps. This innovative design allows the water ring pumps to generate the essential pre-vacuum needed for optimal Screw pump performance. The Screw pump works effectively as a booster, enhancing the vacuum capabilities of the unit. Notably, for each additional stage of Screw pumps added, the ultimate vacuum level can improve by an impressive order of magnitude. As a trusted factory and supplier in China, we ensure high-quality manufacturing standards and reliability in our vacuum pump systems, making us a preferred choice for businesses seeking efficiency and performance.

    Product Characteristics

    01

    High vacuum

    Ultimate vacuum degree 267Pa - 0.5Pa

    02

    Large pumping capacity

    Pumping capacity 30L/S - 20000L/S

    03

    Self-manufactured and produced

    Self-manufactured and produced, with over 40 vacuum-related patent technologies, rated as a national-level high-tech enterprise and a science and technology enterprise, has passed ISO9001 quality management system certification

    04

    Foryou vacuum pump customer cases

    Tsinghua University, Wanguang Food, Hainan Coconut Tree, Coca-Cola, Fuyao Glass Industrial Group, Longliqi Industrial, Adolph Cosmetics, Changhong Chemicals, Chengdu Aircraft, China National Petroleum, Hengyi Caprolactam, Yufeng New Materials, Asia Pharmaceutical Group, Xintianyuan Pharmaceutical, Yuekang Pharmaceutical Group, Deliangfang Pharmaceutical, Yanjing Beer, Baiwei Beer, Chinese Academy of Sciences, Huayuan New Energy, Zunxinnew Energy, etc., 200+ specialized industries and 10000+ customers. The top players in multiple industries are all using Foryou vacuum pumps.

    Product Parameters

    Unit model

    Pump model

    Draw rate

    L/S

    Absolute vacuum

    Pa

    Total power

    KW

    Main pump

    Pre-stage pump

    JZJ2B30-1

    ZJP30

    2BV5110

    30

    267

    5.5

    JZJ2B70-1

    ZJP70

    2BV5111

    70

    7

    JZJ2B150-1

    ZJP150

    2BV5131

    150

    14

    JZJ2B300-2

    ZJP300

    2BV5161

    300

    19

    JZJ2B300-1

    ZJP300

    2BE1 202

    300

    26

    JZJ2B600-2

    ZJP600

    2BE1 203

    600

    44.5

    JZJ2B600-1

    ZJP600

    2BE1 252

    600

    52.5

    JZJ2B70-2.1

    ZJP70

    ZJP30/2BV5110

    70

    25

    7

    JZJ2B150-2.1

    ZJP150

    ZJP70/2BV5111

    150

    10

    JZJ2B300-2.1

    ZJP300

    ZJP150/2BV5131

    300

    18

    JZJ2B600-2.2

    ZJP600

    ZPJ300/2BV5161

    600

    26.5

    JZJ2B1200-2.2

    ZJ1200

    ZJP600/2BE1203

    1200

    55.5

    JZJ2B1200-2.1

    ZJ1200

    ZJP600/2BE1252

    1200

    63.5

    JZJ2B2500-2.1

    ZJ2500

    ZJ1200/2BE1303

    2500

    133

    JZJ2B5000-4.1

    ZJ5000

    ZJ1200/2BE1303

    5000

    176

    JZJ2B70-2.1.1

    ZJP70

    ZJP30/ZJP30/2BV5110

    70

    0.5

    8.5

    JZJ2B150-2.2.1

    ZJP150

    ZJP70/ZJP30/2BV5110

    150

    10

    JZJ2B300-2.2.1

    ZJP300

    ZJP150/ZJP70/2BV5111

    300

    14

    JZJ2B600-2.2.1

    ZJP600

    ZJP300/ZJP150/2BV5131

    600

    23.5

    JZJ2B1200-2.2.2

    ZJ1200

    ZJP600/ZJP300/2BV5161

    1200

    37.5

    JZJ2B1200-2.2.1

    ZJ1200

    ZJP600/ZJP300/2BE1202

    1200

    51.5

    JZJ2B2500-2.2.1

    ZJ2500

    ZJ1200/ZJP600/2BE1252

    2500

    85.5

    JZJ2B2500-4.2.1

    ZJ2500

    ZJP600/ZJP300/2BE1202

    2500

    55.5

    JZJ2B5000-4.2.1

    ZJ5000

    ZJ1200/ZJP600/2BE1252

    5000

    118.5

    ⓘ Important Notes & Explanation
    • 1 The series in the table represents the recommended standards. Due to the varying working conditions in actual production applications, the gas intake and pressure will undergo many changes. Therefore, during the selection process, calculations or reference to the usage of existing equipment should be conducted based on the actual vacuum extraction process, gas release process, condensation of non-volatile gases, time variations of the intake pressure, etc.
    • 2 The technical indicators of the single pump are detailed in the respective pump parameter tables.
    • 3 The maximum intake pressure refers to the highest pressure that the main pump can start at. If it operates for a long time at a pressure higher than this, it will cause the main pump to overload.
    • 4 If the vacuum pump motor, electrical contact vacuum gauge/pressure transmitter, and electrical control cabinet need to be explosion-proof, please specify during the order. The 2BV5 water ring vacuum pump in the table should be correspondingly changed to the 2BV6 series.
    ❓ Frequently Asked Questions (FAQ)
    Q What does the unit model designation (e.g., JZJ2B300-2) mean in the JZJ2B vacuum unit series?
    A The model designation encodes key configuration information: the number following the hyphen indicates the number of pump stages and configuration type, while the number before the hyphen represents the nominal pumping speed (draw rate) in L/S. For example, JZJ2B300-2 features a ZJP300 main pump with a 2BV5161 pre-stage pump and a draw rate of 300 L/S.
    Q How should I select the correct JZJ2B vacuum unit model for my application?
    A Selection should be based on your actual process requirements, including the vacuum extraction process, gas release characteristics, condensation of non-volatile gases, and time-varying intake pressure. The table provides recommended standards, but calculations or reference to existing equipment usage should always be performed to match your specific working conditions.
    Q What is the achievable absolute vacuum level for the JZJ2B series units?
    A The JZJ2B series offers three absolute vacuum levels depending on configuration: 267 Pa for single-stage pre-pump units, 25 Pa for two-stage pre-pump units, and 0.5 Pa for three-stage pre-pump units. Higher-stage configurations achieve deeper vacuum levels suitable for more demanding industrial processes.
    Q What happens if the main pump operates above its maximum intake pressure for an extended period?
    A Operating the main pump continuously at a pressure higher than its rated maximum intake pressure will cause the main pump to overload. This can lead to increased energy consumption, accelerated wear, overheating, and potential mechanical failure. It is critical to ensure the system operates within the specified pressure range during sustained operation.
    Q Can the JZJ2B vacuum units be configured for explosion-proof environments?
    A Yes. If explosion-proof requirements apply to the vacuum pump motor, electrical contact vacuum gauge, pressure transmitter, or electrical control cabinet, this must be specified at the time of ordering. In such cases, the 2BV5 water ring vacuum pump listed in the standard configuration table should be replaced with the corresponding 2BV6 explosion-proof series.
    Q What is the difference between the 2BV5 and 2BE1 pre-stage pump series used in these units?
    A Both are water ring vacuum pumps used as pre-stage (backing) pumps in the JZJ2B units. The 2BV5 series is typically used for smaller to medium draw-rate configurations, while the 2BE1 series is applied in higher-capacity units requiring larger pumping volumes. For explosion-proof applications, the 2BV5 series should be replaced with the 2BV6 series as specified by the manufacturer.

    Leave Your Message