The Screw Water Ring Vacuum Pump Unit is an advanced vacuum solution designed for optimal performance in industrial applications. This unit features a high-efficiency Screw pump as the main pump, complemented by either 2BV or 2BE water ring pumps serving as pre-stage pumps. The primary function of the water ring pump is to generate the necessary pre-vacuum required for the efficient operation of the Screw pump. As a leading supplier in China, we ensure that our vacuum units deliver enhanced performance, with the capability to significantly improve ultimate vacuum levels. By adding additional stages of Screw pumps, users can increase the vacuum degree by an entire order of magnitude, making our products ideal for various manufacturing processes. Trust our factory for innovative vacuum solutions tailored to your needs

    Product Characteristics

    01

    High vacuum

    Ultimate vacuum degree 267Pa - 0.5Pa

    02

    Large pumping capacity

    Pumping capacity 30L/S - 20000L/S

    03

    Energy saving

    5.5KW - 180KW

    04

    Self-manufactured and produced

    Self-manufactured and produced, with over 40 vacuum-related patent technologies, rated as a national-level high-tech enterprise and a science and technology enterprise, has passed ISO9001 quality management system certification

    Product Parameters

    Unit model

    Pump model

    Draw rate

    L/S

    Absolute vacuum

    Pa

    Total power

    KW

    Main pump

    Pre-stage pump

    JZJ2B30-1

    ZJP30

    2BV5110

    30

    267

    5.5

    JZJ2B70-1

    ZJP70

    2BV5111

    70

    7

    JZJ2B150-1

    ZJP150

    2BV5131

    150

    14

    JZJ2B300-2

    ZJP300

    2BV5161

    300

    19

    JZJ2B300-1

    ZJP300

    2BE1 202

    300

    26

    JZJ2B600-2

    ZJP600

    2BE1 203

    600

    44.5

    JZJ2B600-1

    ZJP600

    2BE1 252

    600

    52.5

    JZJ2B70-2.1

    ZJP70

    ZJP30/2BV5110

    70

    25

    7

    JZJ2B150-2.1

    ZJP150

    ZJP70/2BV5111

    150

    10

    JZJ2B300-2.1

    ZJP300

    ZJP150/2BV5131

    300

    18

    JZJ2B600-2.2

    ZJP600

    ZPJ300/2BV5161

    600

    26.5

    JZJ2B1200-2.2

    ZJ1200

    ZJP600/2BE1203

    1200

    55.5

    JZJ2B1200-2.1

    ZJ1200

    ZJP600/2BE1252

    1200

    63.5

    JZJ2B2500-2.1

    ZJ2500

    ZJ1200/2BE1303

    2500

    133

    JZJ2B5000-4.1

    ZJ5000

    ZJ1200/2BE1303

    5000

    176

    JZJ2B70-2.1.1

    ZJP70

    ZJP30/ZJP30/2BV5110

    70

    0.5

    8.5

    JZJ2B150-2.2.1

    ZJP150

    ZJP70/ZJP30/2BV5110

    150

    10

    JZJ2B300-2.2.1

    ZJP300

    ZJP150/ZJP70/2BV5111

    300

    14

    JZJ2B600-2.2.1

    ZJP600

    ZJP300/ZJP150/2BV5131

    600

    23.5

    JZJ2B1200-2.2.2

    ZJ1200

    ZJP600/ZJP300/2BV5161

    1200

    37.5

    JZJ2B1200-2.2.1

    ZJ1200

    ZJP600/ZJP300/2BE1202

    1200

    51.5

    JZJ2B2500-2.2.1

    ZJ2500

    ZJ1200/ZJP600/2BE1252

    2500

    85.5

    JZJ2B2500-4.2.1

    ZJ2500

    ZJP600/ZJP300/2BE1202

    2500

    55.5

    JZJ2B5000-4.2.1

    ZJ5000

    ZJ1200/ZJP600/2BE1252

    5000

    118.5

    ⓘ Explanation
    • 1 The series in the table represents the recommended standards. Due to the varying working conditions in actual production applications, the gas intake and pressure will undergo many changes. Therefore, during the selection process, calculations or reference to the usage of existing equipment should be conducted based on the actual vacuum extraction process, gas release process, condensation of non-volatile gases, time variations of the intake pressure, etc.
    • 2 The technical indicators of the single pump are detailed in the respective pump parameter tables.
    • 3 The maximum intake pressure refers to the highest pressure that the main pump can start at. If it operates for a long time at a pressure higher than this, it will cause the main pump to overload.
    • 4 If the vacuum pump motor, electrical contact vacuum gauge/pressure transmitter, and electrical control cabinet need to be explosion-proof, please specify during the order. The 2BV5 water ring vacuum pump in the table should be correspondingly changed to the 2BV6 series.
    ❓ Frequently Asked Questions
    Q What does the "Absolute Vacuum" value represent in the JZJ2B pump unit specification table?
    A The "Absolute Vacuum" value (in Pa) indicates the ultimate vacuum level that the pump unit can achieve under standard operating conditions. For example, units with a 267 Pa absolute vacuum are suitable for applications requiring a moderate vacuum, while those reaching 0.5 Pa are designed for high-vacuum precision processes.
    Q How should I select the right JZJ2B unit model for my application?
    A Selection should be based on your actual vacuum extraction process requirements, including the required draw rate (L/S), target absolute vacuum level (Pa), and total power availability (KW). It is recommended to also consider the gas release process, non-volatile gas condensation, and intake pressure variations over time. Calculations or reference to existing equipment usage can assist in making the optimal choice.
    Q What is the difference between the "Main pump" and "Pre-stage pump" in the unit configuration?
    A The main pump (e.g., ZJP series or ZJ series roots blower) is responsible for achieving the target high-vacuum level, while the pre-stage pump (e.g., 2BV or 2BE series water ring pump) serves as a backing pump that reduces the pressure to a level at which the main pump can efficiently operate. Together they form a staged vacuum system for higher performance.
    Q What happens if the main pump operates for extended periods above the maximum intake pressure?
    A Operating the main pump above its maximum intake pressure for a prolonged period will cause the pump motor to overload, potentially leading to overheating, increased wear, and equipment failure. It is critical to ensure that the pre-stage pump lowers the system pressure to within the main pump's rated range before and during operation.
    Q When should I specify explosion-proof components for the JZJ2B vacuum pump unit?
    A Explosion-proof components should be specified when the pump unit will be used in environments with flammable gases, vapors, or dust — such as chemical plants, petroleum processing facilities, or solvent handling operations. In such cases, the vacuum pump motor, electrical contact vacuum gauge or pressure transmitter, and electrical control cabinet must all meet explosion-proof standards. Note that the 2BV5 water ring vacuum pump should be replaced with the 2BV6 series accordingly.
    Q Where can I find detailed technical specifications for individual pumps listed in the unit table?
    A Detailed technical indicators for each individual pump — including the ZJP, ZJ, 2BV, and 2BE series — are available in the respective pump parameter tables provided separately. These tables include specifications such as motor power, maximum pumping speed, flange dimensions, and operational pressure ranges for each pump model.

    Leave Your Message